Minimum Requirements
Infrastructure
Connectivity and Bandwidth Requirements
One-way latency (mouth to ear) no more than 150 ms
100 kbits UP/DOWN per concurrent voice call, plus web traffic bandwidth for the Daktela web interface (average is 100kbits DOWN for each active working agent)
Loss no more than 1 percent IP exchanges, VoIP networks
Average one-way jitter targeted at less than 30 ms
Optional: Voice traffic should be marked to DSCP EF per the QoS Baseline and RFC 3246
When using a firewall, the customer must configure and change it for the VoIP and data stream to allow communication between the on premise instance, its phones and the Daktela platform
Disabled SIP-ALG on LAN devices and firewall, as default. May be enabled in some specific cases.
Due to their complexity, Daktela doesn’t provide support for customer LAN infrastructure and firewalls!
Professional LAN network infrastructure based on min. full duplex 100 Mbit/s switches and of type CAT5e or better.
The network must not run at full capacity even during peak hours. Adequate capacity must be available for the anticipated voice traffic. It is ideal to separate and prioritise the telephony data, e.g. via VLAN.
Separate switches for IP phones and PCs are recommended for high volume data exchange over the local network.
IP phones must be assigned a valid IP configuration including internet gateway designated for voice traffic by means of a DHCP server.
For On-Premise Daktela Installations
Open Ports for Backup, Monitoring and Remote Management
Incoming ports TCP usually 22 (SSH) from: backup.daktela.com - 82.113.42.139; gw.daktela.com - 95.80.200.192; zabbix.daktela.com - 82.113.42.131
Outgoing: For upgrade and monitoring purposes of on-premise installations, full access to the Internet is preferred. If it is not possible, please contact Daktela support to set up the necessary firewall exceptions.
For Daktela Implementations in the Daktela Cloud
Allowed Ports for WebRTC Phones
For WebRTC phones
outgoing 8089/tcp to ip list
incoming and outgoing 10000-20000/udp from/to ip list
For PBX
incoming 5060/udp from ip list
incoming and outgoing 10000-20000/udp from/to ip list
IP list
194.176.107.3/32, 194.176.107.4/32, 194.176.107.5/32, 194.176.107.6/32, 194.176.107.7/32, 194.176.107.8/32, 194.176.107.9/32, 194.176.107.10/32, 194.176.107.12/32, 194.176.107.13/32
45.133.137.215/32, 45.133.137.217/32, 45.133.137.219/32, 45.133.137.221/32, 45.133.137.224/32, 45.133.137.225/32
Allowed Ports for SIP Phones
Open outgoing port ( to pbx ): 5061/TCP
Open incoming/outgoing port ( from/to pbx ): 5060/UDP, 10000-20000/UDP
Outgoing
Full access to the IP address of the cloud pbx is preferred (can optionally be further limited to these outgoing ports: TCP/80, TCP/443, ICMP, TCP/20, TCP/21, TCP/UDP/123, TCP/44000-44100)
Browsers
Min. browser requirements
Daktela supports the latest versions of Chrome, Firefox, Opera , Safari, Edge
Min. requirements for Daktela Wallboards
Daktela supports the latest versions of Chrome, Firefox, Opera , Safari, Edge. Wallboards can also run on Smart TVs and LCDs with the latest versions of supported browsers.
Hardware and Phones
Software IP Phones
We support SW phones – see our Documentation.
SW phones for Windows – Microsip – download the Daktela branded version – or Linphone.
SW phones for MacOS – Telephone (available in the App Store), Zoiper or Linphone.
Support
While Daktela V6 should work with all of the SW phones above, Daktela provides support only for the Daktela Software Phone.
Hardware IP Phones
Suggested HW phones: Yealink IP phones, Cisco SPA, Siemens Gigaset
Phone transport set as UDP, allowed codecs G.711 A-law
Min. computer requirements
PC with CPU min. 2.0 GHz (4+ cores ), min. 8 GB RAM (16 GB RAM preferred), Audio In/Out
MacBook with min. 8 GB RAM (16 GB RAM preferred)
Emails and Tickets
Requirements to Send and Receive Email Using the Daktela Helpdesk
Daktela must be the only mail client using the mailbox.
The customer must be aware of the allowed quantity of sent emails to prevent blocking etc.
The customer must provide:
access to the incoming and outgoing mail server.
any additional required parameters.